Evaluation of rotator cuff tendinopathies and tears with high-resolution ultrasonography and magnetic resonance imaging correlation


Zubair Ahmad, Mohd Ilyas, Gh. Mohammad Wani, Naseer A Choh, Tariq A Gojwari, Mir Junaid Ahmad Kazime 
 Department of Radiodiagnosis, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India

Correspondence Address:
Dr. Mohd Ilyas
Department of Radiodiagnosis, Sher-I-Kashmir Institute of Medical Sciences, Soura, Srinagar - 190 011, Jammu and Kashmir
India

Background: The aim of this study was to assess the accuracy of high-resolution ultrasonography (USG) in the evaluation of rotator cuff tendinopathies and tears with magnetic resonance imaging (MRI) correlation to determine its sensitivity and specificity. Materials and Methods: The prospective study was conducted on 40 patients referred to the Department of Radiology for the evaluation of rotator cuff pathologies over a period of 18 months. All the patients underwent high-frequency USG followed by MRI. Variables such as sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of high-frequency USG and MRI were evaluated. Results: The sensitivity, specificity, NPV, PPV, and accuracy of high-frequency USG in the evaluation of rotator cuff pathologies in comparison to MRI as standard were 90.6%, 87.5%, 96.6%, 70%, and 90%, respectively. Conclusion: High-frequency USG is almost equally sensitive and specific as MRI for the diagnosis of rotator cuff pathologies, and due to its cost-effectiveness, easy affordability, ease of evaluating contralateral shoulder, more patient compliance, noninvasiveness, and wider applications, we recommend it to be used as a primary modality for evaluating rotator cuff. MRI should be performed in case some extra information is required.


How to cite this article:
Ahmad Z, Ilyas M, Wani GM, Choh NA, Gojwari TA, Ahmad Kazime MJ. Evaluation of rotator cuff tendinopathies and tears with high-resolution ultrasonography and magnetic resonance imaging correlation.Arch Trauma Res 2018;7:15-23


How to cite this URL:
Ahmad Z, Ilyas M, Wani GM, Choh NA, Gojwari TA, Ahmad Kazime MJ. Evaluation of rotator cuff tendinopathies and tears with high-resolution ultrasonography and magnetic resonance imaging correlation. Arch Trauma Res [serial online] 2018 [cited 2024 Mar 29 ];7:15-23
Available from: https://www.archtrauma.com/article.asp?issn=2251-953X;year=2018;volume=7;issue=1;spage=15;epage=23;aulast=Ahmad;type=0